Dock leveler, door, seal or restraint down in Sparks or Reno? Send a service request →

← All guides

Loading Dock Safety Requirements in Nevada: Dock Levelers, Dockboards and Trailer Movement

Key takeaways

  • Reno-Sparks warehouses fall under Nevada OSHA, a State Plan that has incorporated most federal OSHA standards by reference.
  • Dockboards must support the maximum intended load, and units first put into service on or after January 17, 2017 need run-off protection (29 CFR 1910.26).
  • Something, such as wheel chocks or sand shoes, must keep the trailer from moving while people are on the dockboard (1910.26(d)).
  • A damaged leveler has to be repaired or guarded before anyone uses it, and structural repairs need a qualified person (1910.22(d)).
  • Manufacturer manuals set the maintenance interval: quarterly for single-shift, monthly for multi-shift in Blue Giant's hydraulic manual.

Send a dock repair or inspection request →

Every loading dock in the Reno-Sparks industrial corridor runs on the same few pieces of equipment: a leveler or dockboard to bridge the gap, something to keep the trailer still, and a door and seal around it all. This guide pulls together the safety rules that apply to that equipment in Nevada and the maintenance intervals manufacturers publish, so a warehouse or maintenance manager can see what is required, what is recommended, and what to put in a service request.

What counts as a dockboard

OSHA's rule for dockboards, 29 CFR 1910.26, covers the plates and bridges that span the gap between a dock and a transport vehicle such as a truck, semi-trailer, trailer or rail car. Portable dock plates are dockboards. Built-in hydraulic, mechanical and air-powered dock levelers do the same job from a pit or the dock edge, which is why most facilities apply the dockboard rules to them as well.

Who enforces the rules in Reno and Sparks

Nevada has run an OSHA-approved State Plan since 1974. According to federal OSHA's Nevada State Plan page, Nevada OSHA is part of the Division of Industrial Relations in the Department of Business and Industry, covers most private-sector workplaces in the state, keeps an office in Reno, and has incorporated most federal OSHA standards by reference. The rules below are the federal text; check Nevada OSHA for any state-specific requirement.

The federal dockboard rules, line by line

29 CFR 1910.26 Dockboards
ParagraphRequirementWhat to check on your dock
(a)Dockboards are capable of supporting the maximum intended load (per 1910.22(b)).Know the rated capacity on the serial plate and whether today's forklifts and loads stay under it.
(b)(1)Dockboards put into initial service on or after January 17, 2017 are designed, constructed and maintained to prevent transfer vehicles from running off the edge.Newer units: confirm curbs, toe guards or other run-off protection are intact.
(b)(2)Exception where the employer demonstrates there is no run-off hazard.Document the reasoning if you rely on it.
(c)Portable dockboards are anchored or otherwise secured so they cannot move out of a safe position.Dock plates: check anchoring pins or locking legs.
(d)Measures such as wheel chocks or sand shoes prevent the transport vehicle from moving while employees are on the dockboard.Chocks or a vehicle restraint at every active door, and a procedure that people follow.
(e)Portable dockboards have handholds or other means for safe handling.Dock plates: handles present and usable.

When a leveler is damaged

29 CFR 1910.22(d) Inspection, maintenance and repair of walking-working surfaces
ParagraphRequirementIn practice
(d)(1)Surfaces are inspected regularly and as necessary, and kept in safe condition.Daily operator checks plus planned maintenance visits.
(d)(2)Hazardous conditions are corrected or repaired before employees use the surface again, or guarded until repaired.Tag the door out of service; do not run forklifts over a leveler that drifts, cracks or will not hold.
(d)(3)Structural repairs are performed or supervised by a qualified person.Deck, lip, hinge and frame repairs go to a qualified technician.

Source: 29 CFR 1910.22.

What the manufacturer manuals add

OSHA sets the duty to inspect and repair but not the interval. Manufacturer manuals fill that in. Two published examples:

Published maintenance guidance for hydraulic dock levelers
ItemBlue Giant hydraulic leveler manualNordock CH 25-45K manual
Planned maintenance by a technicianEvery 3 months for single-shift, monthly for multi-shift operationsTask-based schedule below
Daily checksOperator daily inspection and daily maintenance checklistNot listed in the table
Lip hingeNot broken out separately; see the manualGrease every 90 days
Cylinder pivot pins and dock hingeNot broken out separately; see the manualLight oil every 90 days
Hydraulic oilNot broken out separately; see the manualCheck level every 90 days; change yearly; clean strainer and magnet yearly; minimum ISO grade 32
PitNot broken out separately; see the manualClean every 90 days or as required
Working under the deckLockout/tagout; dock strut and service stand in placeLockout; maintenance stands in place
Who does the workA qualified dock leveler repair technicianHydraulic work by a qualified hydraulic technician; electrical by a qualified electrician
Warranty notesExceeding the serial-plate load classification voids the warrantyUsing lubricants other than those specified voids warranty claims

Sources: Blue Giant hydraulic dock leveler owner's manual, Rev. 1.7 and Nordock CH 25-45K manual. Other brands publish their own schedules; use the manual for the unit on your dock.

How we put this guide together

Scenario guidance

A leveler drifts down or will not hold under load

Take the door out of service now (1910.22(d)(2)). Hydraulic leaks and lost holding pressure are hydraulic work for a qualified technician. Send the brand, model, door number and symptoms through a dock leveler repair request in Reno & Sparks.

You run two or three shifts

Blue Giant's manual moves planned maintenance from quarterly to monthly for multi-shift docks. Price a hydraulic dock leveler maintenance program on that basis.

The deck or lip is cracked, bent or the unit predates run-off protection

Structural repair needs a qualified person (1910.22(d)(3)). If repair is not practical, a replacement unit put into service now must meet 1910.26(b)(1). See dock leveler replacement in Reno & Sparks.

Trailers creep away from the dock

That is a 1910.26(d) problem. Check that chocks are used every time, or have a truck restraint repaired if one is installed.

Request dock equipment service →

Frequently asked questions

Does Nevada have its own OSHA rules for loading docks?

Nevada runs an OSHA-approved State Plan through Nevada OSHA, part of the Division of Industrial Relations, which covers most private-sector workplaces in the state and has a Reno office. Federal OSHA describes Nevada as having incorporated most federal OSHA standards by reference, so the federal dockboard and walking-working surface rules are the baseline for Reno-Sparks warehouses. Check Nevada OSHA for any state-specific additions.

Is a dock leveler a dockboard under OSHA?

OSHA's 29 CFR 1910.26 covers dockboards, the bridging plates that span the gap between a dock and a transport vehicle, and its requirements are written for dockboards generally. Built-in dock levelers do that same bridging job, so most facilities apply 1910.26 to them. If your situation is unusual, ask Nevada OSHA's consultation program.

Do I have to use wheel chocks or a vehicle restraint?

OSHA 1910.26(d) requires measures, such as wheel chocks or sand shoes, to keep the truck, trailer or rail car from moving while employees are on the dockboard. It names chocks and sand shoes as examples rather than requiring one device, so many docks use powered or mechanical vehicle restraints as their measure. Whatever you use has to work every time.

Do older dock levelers need run-off protection?

OSHA 1910.26(b)(1) requires run-off protection on dockboards put into initial service on or after January 17, 2017. Older units are not covered by that paragraph, but they still must support the maximum intended load (1910.26(a)) and be repaired or guarded when hazardous (1910.22(d)(2)).

How often should a hydraulic dock leveler be serviced?

Follow your manufacturer. Blue Giant's hydraulic leveler manual recommends planned maintenance by a qualified technician every three months for single-shift operations and monthly for multi-shift operations. Nordock's CH 25-45K manual lists lubrication, oil-level and pit-cleaning tasks every 90 days and an oil change yearly.

Who is allowed to repair a damaged dock leveler?

OSHA 1910.22(d)(3) requires that when a walking-working surface needs structural repair, a qualified person performs or supervises it. Nordock's manual also says hydraulic work must be done by a qualified hydraulic technician and electrical work by a qualified electrician.

Related guides

Send a request →